Fluke 773 Milliamp Process Clamp Meter Description
The Fluke 773 Milliamp process clamp meter is useful when troubleshooting transmitters, valves, PLC and DCS I/O. It allows you to troubleshoot and repair 4-20 mA loops without breaking the loop, which then saves you a lot of time and effort. What’s more, unlike conventional clamp meters, the meter features a remote jaw that connects to the main body via extension cable. We offer the Fluke 773 to rent for just £50 per week.
Features and Benefits
- In-circuit measurement of 0-24 mA dc, up to 99.9 mA dc
- Loop power supply 24 V dc output
- Simultaneous mA measurement via detachable clamp and mA sourcing
- Electronic zero
- Auto power off (battery saver)
- Display backlight
- Measurement spotlight LED
Product Specs
- Diameter of measurable conductor: 0.177 or 4.5 mm max
- Operating temperature: -10 to 50 ºC
- Storage Temperature: -25 to 60ºC
- Operating Humidity: < 90% @ <30 ºC, < 75% @ 30 to 55ºC
- Operating Altitude: 0 to 2000 m
- IP Rating: IP 40
- Size: 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
- Weight: 410 g, (14.4 oz)
- Vibration: Random 2 g, 5 to 500 Hz
- Shock: 1 meter drop test (except the jaw)
- EMI/RFI: Meets EN61326-1. Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
- Temperature Coefficient: 0.01% ºC (<18ºC or > 28ºC)
- Power, battery life: (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
- mA measurement (Measured by clamp): Resolution and Range: 0 to 20.99 mA, Accuracy: 0.2%+5 counts. Resolution and Range: 21.0 mA to 100.0 mA, Accuracy: 1% + 5 counts
- mA measurement (Measured in series with test jacks): Resolution and Range: 0 to 24.00 mA, Accuracy: 0.2% + 2counts
- mA source (Maximum mA Drive: 24 mA into 1,000 ohms): Resolution and Range: 0 to 24.00 mA, Accuracy: 0.2% + 2counts
- mA simulate (Maximum voltage 50 V dc): Resolution and Range: 0 to 24.00 mA, Accuracy: 0.2% + 2counts
- Voltage source (2 mA maximum drive current): Resolution and Range: 0 to 10.00 V dc, Accuracy: 0.2% + 2counts
- Voltage Measure: Resolution and Range: 0 to 30.00 V dc, Accuracy: 0.2% + 2counts